Search results for "Time of Flight"
showing 10 items of 114 documents
2020
Time-resolved photoemission with ultrafast pump and probe pulses is an emerging technique with wide application potential. Real-time recording of nonequilibrium electronic processes, transient states in chemical reactions, or the interplay of electronic and structural dynamics offers fascinating opportunities for future research. Combining valence-band and core-level spectroscopy with photoelectron diffraction for electronic, chemical, and structural analyses requires few 10 fs soft X-ray pulses with some 10 meV spectral resolution, which are currently available at high repetition rate free-electron lasers. We have constructed and optimized a versatile setup commissioned at FLASH/PG2 that c…
Conceptual study of a heavy-ion-ERDA spectrometer for energies below 6 MeV
2017
Abstract Elastic recoil detection analysis (ERDA) is a well established technique and it offers unique capabilities in thin film analysis. Simultaneous detection and depth profiling of all elements, including hydrogen, is possible only with time-of-flight ERDA. Bragg ionization chambers or Δ E - E detectors can also be used to identify the recoiling element if sufficiently high energies are used. The chief limitations of time-of-flight ERDA are the beam induced sample damage and the requirement of a relatively large accelerator. In this paper we propose a detector setup, which could be used with 3 MeV to 6 MeV medium heavy beams from either a single ended accelerator (40Ar) or from a tandem…
Analysis of thin high-k and silicide films by means of heavy ion time-of-flight forward-scattering spectrometry
2006
The use of forward scattered heavy incident ions in combination with a time-of-flight-energy telescope provides a powerful tool for the analysis of very thin (5–30 nm) films. This is because of greater stopping powers and better detector energy resolution for heavier ions than in conventional He-RBS. Because of the forward scattering angle, the sensitivity is greatly enhanced, thus reducing the ion beam induced desorption during the analysis of very thin films. The drawback of forward scattering angle is the limited mass separation for target elements. We demonstrate the performance of the technique with the analysis of 25 nm thick NiSi films and atomic layer deposited 6 nm thick HfxSiyOz f…
Simulations on time-of-flight ERDA spectrometer performance
2016
The performance of a time-of-flight spectrometer consisting of two timing detectors and an ionization chamber energy detector has been studied using Monte Carlo simulations for the recoil creation and ion transport in the sample and detectors. The ionization chamber pulses have been calculated using Shockley-Ramo theorem and the pulse processing of a digitizing data acquisition setup has been modeled. Complete time-of-flight–energy histograms were simulated under realistic experimental conditions. The simulations were used to study instrumentation related effects in coincidence timing and position sensitivity, such as background in time-of-flight–energy histograms. Corresponding measurement…
Analysis of psychoactive substances in water by information dependent acquisition on a hybrid quadrupole time-of-flight mass spectrometer.
2016
Emerging drugs of abuse, belonging to many different chemical classes, are attracting users with promises of “legal” highs and easy access via internet. Prevalence of their consumption and abuse through wastewater-based epidemiology can only be realized if a suitable analytical screening procedure exists to detect and quantify them in water. Solid-phase extraction and ultra-high performance liquid chromatography quadrupole time-of-flight-mass spectrometry (UHPLC–QqTOF–MS/MS) was applied for rapid suspect screening as well as for the quantitative determination of 42 illicit drugs and metabolites in water. Using this platform, we were able to identify amphetamines, tryptamines, piperazines, p…
Development of a database for the rapid and accurate routine identification of Achromobacter species by matrix-assisted laser desorption/ionization-t…
2019
International audience; Objectives: Achromobacter spp. are emerging pathogens in respiratory samples from cystic fibrosis patients. The current reference methods (nrdA-sequencing or multilocus sequence typing) can identify 18 species which are often misidentified by conventional techniques as A. xylosoxidans. A few studies have suggested that matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF/MS) provides accurate identification of the genus but not of species. The aims of this study were (a) to generate a database for MALDI-TOF/MS Bruker including the 18 species, (b) to evaluate the suitability of the database for routine laboratory identification, and …
Improvement of a rapid direct blood culture microbial identification protocol using MALDI-TOF MS and performance comparison with SepsiTyper kit
2018
Fast diagnosis of pathogens is critical to guarantee the most adequate therapy for infections; bacterial culture methods, which constitute the actual gold standard, are precise and sensitive but rather slow. Today, new methods have been made available to enable faster diagnosis, with the Matrix-Assisted Laser Desorption Ionization-Time Of Flight Mass Spectrometry (MALDI-TOF MS) technique being the most promising. Even if simpler and faster than traditional bacterial culture methods, analysis of positive blood cultures via MALDI-TOF MS requires a preliminary extraction process of samples. In this study, we compared two extraction protocols for bacterial identification directly from positive …
Particle identification in ALICE: a Bayesian approach
2016
We present a Bayesian approach to particle identification (PID) within the ALICE experiment. The aim is to more effectively combine the particle identification capabilities of its various detectors. After a brief explanation of the adopted methodology and formalism, the performance of the Bayesian PID approach for charged pions, kaons and protons in the central barrel of ALICE is studied. PID is performed via measurements of specific energy loss ($\mathrm{d}E/\mathrm{d}x$) and time-of-flight. PID efficiencies and misidentification probabilities are extracted and compared with Monte Carlo simulations using high-purity samples of identified particles in the decay channels ${\rm K}^0_S \righta…
3D reconstruction of hot metallic surfaces for industrial part characterization
2009
During industrial forging of big hot metallic shells, it is necessary to regularly measure the dimensions of the parts, especially the inner and outer diameters and the thickness of the walls, in order to decide when to stop the forging process. The inner and outer diameters of the shells range from 4 to 6 meters and to measure them a large ruler is placed horizontally at the end of the shell. Two blacksmiths standing on each side of the ruler at about ten meters from it visually reads the graduations on the ruler in order to determine the inner and outer diameters from which the thickness of the wall is determined. This operation is carried out several times during a forging process and it…
Application of time-of-flight aerosol mass spectrometry for the online measurement of gaseous molecular iodine.
2012
Here we present a new application of a time-of-flight aerosol mass spectrometer (TOF-AMS) for the measurement of atmospheric trace gases in real-time. Usually, TOF-AMS instruments are not sensitive to gas-phase species due to the aerodynamic particle focusing inlet system which reduces the gas phase species by a factor of about 10(7) relative to the particle phase. This efficient removal of the gas phase and the resulting high relative enrichment of particles is one reason for the very high sensitivity of TOF-AMS instruments for particle phase compounds (detection limits in the sub-μg/m(3)-range for online measurements with 1 min integration time), which allows application of the instrument…